NETGEAR ProSafe SSL VPN Concentrator 25 SSL312 Reference Manual

2-4

Installing the SSL312

v1.1, November 2006

2. Configure your PC with a static IP address of 192.168.1.10 and 255.255.255.0 as the

subnet mask.

3. Connect an Ethernet cable from your computer to Ethernet Port 1 on the front of the SSL VPN

Concentrator.

4. Connect the power cord to the SSL312, turn on the concentrator and verify the following:

The PWR (power) light goes on immediately.

The TEST light goes off after about one minute, indicating that the system has initialized.

One of the Ethernet lights is lit: either the 10 Mbps or the 100 Mbps LED should light
showing that a connectivity link as been established

Accessing the Management Interface

Using the PC with the static IP address configured, you can log into the SSL VPN Concentrator
web management interface. The initial administrative setup of the concentrator must be performed
using a supported browser listed in

“Web Browser Requirements” on page 1-2

. The machine used

for management is referred to as the “Management Station”.

To log into the management interface:

1. Connect to the SSL312 by opening your browser and entering https://192.168.1.1 (for the

Ethernet Port 1 IP) in the address field. Be sure to type https, not http..

If you are connected to Ethernet Port 2 IP, the default address is https://10.0.0.1.

Note: You must have administrative access to the SSL VPN Concentrator to configure the

Management Interface settings

Figure 2-2

https://192.168.1.1