Functional description – Nortel Networks 1000 User Manual

Page 260

Advertising
background image

260

NT5D33 and NT5D34 Lineside E1 Interface cards

red alarm condition such as not receiving a signal, or the signal exceeds
bit-error thresholds or frame-slip thresholds, a yellow alarm signal is sent
to the LEI, if the terminal equipment supports this feature. If a yellow alarm
signal is detected, the LED turns on.

The MAINT LED indicates if LEI is fully operational because of
certain maintenance commands that are issued through the MMI.
See

“Man-Machine E1 maintenance interface software” (page 284)

for

information on E1 link maintenance. If the card detects that tests are
being run or that alarms are disabled through the MMI, the LED lights and
remains lit until these conditions are no longer detected, then it turns off.

Functional description

Figure 56 "LEI card - block diagram" (page 260)

shows a block diagram of

the major functions contained on the LEI card. Each of these functions is
described on the following pages.

Figure 56
LEI card - block diagram

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising