Option settings

Table 13
OPS analog line card configuration (cont’d.)

Application

On-premise station (ONS)

Off-premise station (OPS)

Class of Service
(CLS) (Note 1)

ONP

OPX

Loop loss (dB)
(Note 3)

0–1.5

>1.5–2.5

>2.5–3.0

0–1.5

>1.5–2.5

>2.5–4.5

>4.5–15

TIMP
(Notes 1, 4)

600

ohms

600

ohms

600

ohms

600

ohms

600

ohms

600

ohms

600

ohms

Class of Service
(CLS) (Note 1)

ONP

OPX

BIMP
(Notes 1, 4)

600

ohms

3COM1

3COM2

600

ohms

3COM1

3COM2

3COM2

Gain treatment
(Note 5)

No

Yes

Note 1: Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).

Note 2: The maximum signaling range supported by the OPS analog line card is 2300 ohms.

Note 3: Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to
loop resistance ranges for 26 AWG wire.

Note 4: Default software impedance settings are:

TIMP:

BIMP:

ONP CLS
600 ohms
600 ohms

OPX CLS

600 ohms

3COM2

Note 1: Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual OPS
loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss greater than 15
dB (equivalent to a maximum signaling range of 2300 ohms on 26 AWG wire) is not recommended.

Note 2: Jumper strap settings JX.0 and JX.1 apply to all eight units; "X" indicates the unit number,
0–7. "Off" indicates that a jumper strap is not installed across both pins on a jumper block. Store
unused straps on the OPS analog line card by installing them on a single jumper pin as shown below:

NT5D12 Dual DTI/PRI (DDP) card

Switch setting tables for this card are listed in subsections according to
their function. Bold font designates factory (default) settings.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.