Architecture

345

Use

Table 146 "Switch setting for MSDL external card" (page 345)

to set

the card address.

Table 146
Switch setting for MSDL external card

Switch Setting

DNUM (LD 17)

1

2

3

4

0

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON

Architecture

Clock operation

There are two types of clock operation - tracking mode and free-run mode.

Tracking mode

In tracking mode, the DDP2 loop supplies an external clock reference to
a clock controller. Two DDP2 loops can operate in tracking mode, with
one defined as the primary reference source for clock synchronization,
the other defined as the secondary reference source. The secondary
reference acts as a back-up to the primary reference.

As shown in

Figure 95 "Clock Controller primary and secondary tracking"

(page 346)

, a system with dual CPUs can use two clock controllers (CC-0

and CC-1). One clock controller acts as a back-up to the other. The clock
controllers should be completely locked to the reference clock.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008