Architecture

975

The transmitter takes the binary data (dual unipolar) from the PCM
transceiver and produces bipolar pulses for transmission to the external
digital facility. The DS1 transmit equalizer allows the cabling distance to be
extended from the card to the DSX-1 or LD-1 configured in LD 17.

The transmitter takes the binary data (dual unipolar) from the PCM
transceiver and produces bipolar pulses for transmission to the external
digital facility. The Digital Signal – Level 1 (DS-1) transmit equalizer
enables the cabling distance to be extended from the card to the Digital
Signal Cross-connect – Level 1 (DSX-1), or LD-1. Equalizers are switch
selectable through dip-switches. The settings are shown in

Table 410

"NTRB21 switch settings" (page 975)

.

Table 410
NTRB21 switch settings

Switch Setting

Distance to Digital

Cross-Connect

1

DCH F/W

2

(LEN 0)

3

(LEN 1)

4

(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

Receiver

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS-1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS1 signal source.

The receiver extracts data and clock from an incoming data stream and
outputs clock and synchronized data. At worst case DSX-1 signal levels,
the line receiver operates correctly with up to 655 feet of ABAM cable
between the card and the external DS-1 signal source.

Connector pinout

The connection to the external digital carrier is through a 15 position Male
D-type connector.

Nortel Communication Server 1000