NT5D97 Dual-port DTI2 PRI2 card

8

Pack and store the NT5D97 card and circuit card.

--End--

Configuring the NT5D97

After the NT5D97 DDP2 is installed, configure the system using the same
procedures as the standard NT8D72BA PRI2.

Consider the following when configuring the NT5D97 DDP2 card:

The CS 1000 software allows four ports to be defined for the NT6D80
MSDL. The DDCH (NTBK51AA) card has only two ports, 0 and
1; therefore, ports 2 and 3 must not be defined when using the
NTBK51AA.

Port 0 of the NTBK51AA can only be defined to work with Loop 0 of
the NT5D97 DDP2 card, and Port 1 of the NTBK51AA can only be
defined to work with Loop 1 of the NT5D97. This relationship must be
reflected when configuring a new DCH in LD 17 (in response to the
DCHL prompt, enter either 0 or 1 when specifying the loop number
used by the DCH).

You cannot define one of the DDP2 loops for the NTBK51AA DDCH,
and the other loop for the NT6D11AF/NT5K75AA/NT5K35AA DCH
card or the NT6D80 MSDL.

When configuring the NT5D97 DDP2 in DTI2 outgoing dial pulse mode,
a Digit Outpulsing patch is required.

Testability and diagnostics

The DDP2 card supports testing and maintenance functions through the
following procedures:

Selftest upon power up or reset

Signalling test performed in the LD 30

Loopback tests, self tests, and continuity tests performed by LD 60
and LD 45

The D-Channel (DCH, MSDL, DDCH) maintenance is supported by
LD 96.

Note:

The MSDL self-test is not applicable to the NTBK51AA

D-Channel daughterboard.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311