Switch sw2 - carrier impedance configuration, Switch sw3 - clock controller configuration, Switch sw4 - carrier shield grounding – Nortel Networks 1000 User Manual

Page 829

Advertising
background image

Physical description

829

Switch SW2 - Carrier Impedance Configuration

This switch sets the carrier impedance to either 120 ohms or 75 ohms.
Twisted pair cable is usually associated with 120 ohms. Coaxial cable is
usually associated with the 75 ohms setting.

Table 345
Switch SW2

Cable Type

SW 2-1

SW 2-2

75 ohms

Up (Off)

Down (On)

120 ohms

Down (On)

Up (Off)

Switch SW3 - Clock Controller Configuration

This switch enables/disables (H/W) the on-board Clock Controller. Disable
the SW 3-2 if the on-board clock controller is not in use.

Table 346
Switch SW3

Switch

Down (On)

Up (Off)

Note

SW 3-1

Spare

SW 3-2

Disabled

Enabled

Switch SW4 - Carrier Shield Grounding

This switch enables for the selective grounding of the Tx / Rx pairs of the
carrier cable. Closing the switch (down position) applies Frame Ground
(FGND) to the coaxial carrier cable shield, creating a 75 ohms unbalanced
configuration. This applies only to the NTBK05CA cable.

Table 347
Switch SW4

Switch

Down (On)

Up (Off)

SW 4-1

Rx – FGND

Rx – OPEN

SW 4-2

Tx – FGND

Tx – OPEN

The usual method is to ground the outer conductor of the receive coaxial
signal.The NTAK79 card incorporates four on-board dip switches. The
tables that follow provide information on the various settings and related
functions of these switches.

Note:

The ON position for all the switches is towards the bottom of the

card. This is indicated by a white dot printed on the board adjacent to
the bottom left corner of each individual switch.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.