Configuring the QSDI paddle board

735

Once the board has been installed, the system software must be
configured to recognize it. Instructions for doing this are found in the
section titled

“Software service changes” (page 728)

.

Option switch settings

Baud rate

Switches SW13, SW10, SW11, and SW12 determine the baud rate for
ports 1, 2, 3, and 4, respectively. See the settings for these switches in

Table 292 "NT8D41BA baud rate switch settings" (page 735)

.

Table 292
NT8D41BA baud rate switch settings

SW13 (port 1),
SW10 (port 2),

SW11 (port 3), SW12 (port 4)

Baud

rate

Baud Clock

(kHz)

1

2

3

4

150

2.40

on

off

on

on

300

4.80

on

on

off

on

600

9.60

on

off

off

on

1,200

19.20

on

on

on

off

2,400

38.40

on

off

on

off

4,800

76.80

on

on

off

off

9,600

153.60

on

off

off

off

19,200*

307.20

on

on

on

on

* For future use.

Address

Switch SW15 or SW16 and logic on the card always address the four
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 14 and 15.
The settings for both switches are shown in

Table 293 "NT8D41BA

address switch settings" (page 736)

. To avoid system problems,

switches SW15 and SW16 must not be configured identically.

Figure 249

"NT8D41BA QSDI paddle board" (page 731)

displays SW15 and SW16.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008