Disconnect supervision – Nortel Networks 1000 User Manual

Page 281

Advertising
background image

Installation

281

Table 109
Card unit number to E1 channel mapping (cont’d.)

Item

TN

E1 Channel Number

Daughterboard

4

22

Daughterboard

5

23

Daughterboard

6

24

Daughterboard

7

25

Daughterboard

8

26

Daughterboard

9

27

Daughterboard

10

28

Daughterboard

11

29

Daughterboard

12

30

Daughterboard

13

31

Disconnect supervision

The LEI supports far-end disconnect supervision by opening the tip side
toward the terminal equipment upon the system’s detecting a disconnect
signal from the far-end on an established call. The Supervised Analog
Line feature (SAL) must be configured in LD 10 for each LEI port. At the
prompt FTR respond:

OSP <CR>

Against FTR respond:

ISP <CR>

The LEI treats OSP and ISP for both originating and terminating calls
as hook flash disconnect supervision, also known as cut-off disconnect.
Originating calls are outgoing from the terminal equipment. Terminating
calls are incoming to the terminal equipment. The LEI does not support
battery reversal answer and disconnect supervision on originating calls.

After the software is configured, power-up the card and verify the self-test
results. The STATUS LED on the faceplate indicates whether or not the
LEI has successfully passed its self test, and is, therefore, functional.
When the card is installed, this LED remains lit for two to five seconds as
the self-test runs. If the self-test completes successfully, the LED flashes
three times and remains lit. When the card is configured and enabled in
software, the LED goes out. The LED goes out if either the motherboard or
daughterboard is enabled by the software. If the LED continually flashes or
remains weakly lit, replace the card.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising