Foreign and surge voltage protection – Nortel Networks 1000 User Manual

Page 598

Advertising
background image

598

NT8D14 Universal Trunk card

Table 212
Power requirements (cont’d.)

Voltage

Tolerance

Current (max.)

–15.0 V dc

±5%

306 mA

+5.0 V dc

±5%

750 mA

+8.5 V dc

±2%

450 mA

–48.0 V dc

±5%

415 mA

Power to the NT8D14 Universal Trunk Card is provided by the module
power supply (ac or dc).

Table 213
Power requirements for universal trunk card

Voltage

Tolerance

Current (max.)

+15.0 V dc

±5%

306 mA

–15.0 V dc

±5%

306 mA

+5.0 V dc

±5%

750 mA

+8.5 V dc

±2%

450 mA

–48.0 V dc

±5%

415 mA

Power requirements for the Universal Trunk Card are specified in

Table

214 "Power requirements" (page 598)

.

Table 214
Power requirements

Voltage

Tolerance

Idle current

Active current

± 15.0 V DC

± 5%

306 ma

306 ma

+ 8.5 V DC

± 2%

120 ma

120 ma

- 48.0 V DC

± 5%

346 ma

346 ma

+ 5.0 V DC

± 10%

350 ma

350 ma

Foreign and surge voltage protection

The NT8D14 Universal Trunk card meets UL-1489 and CS03 over-voltage
(power cross) specifications and FCC Part 68 requirements.

The universal trunk card meets UL-1489 and CS03 over-voltage (power
cross) specifications and FCC Part 68 requirements.

The Universal Trunk Card meets CS03 overvoltage (power cross)
specifications.

The NT8D14 Universal Trunk Card meets UL-1489 and CS03 over-voltage
(power cross) specifications and FCC Part 68 requirements.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising