APPLYING POWER (Side View)

Unscrew & Remove the DC Voltage Input
Plug from the Power Input Header

Install the DC Power Cables into the Plug
(observing polarity).

For best results keep the power cable length
to a maximum of one (1) meter.

Plug the Voltage Input Plug back into the
Power Input Header.

Tightening torque for the terminal block
power plug is 0.5 Nm/0.368 Pound Foot.

Verify the Power LED stays ON (GREEN).

Note: Only 1 power supply must be connected to power for minimal operation. For redundant power
operation, V

1

and V

2

inputs must be connected to separate DC Voltage sources. This device will draw

current from both sources simultaneously. Use 16-28 gauge wire when connecting to the power supply.

Recommended 24V DC Power Supplies, similar to: N-Tron’s P/N NTPS-24-3:

Input AC 115/230V

Output DC 24-28V

Output Current 3A @ 24V

2.6A @ 28V

Power 72W

35 mm DIN-Rail Mountable

Dimensions: 45X75X91 mm