14.3

Listing of Global Messages

Error

Code

Message

Description

Canceling and Re-

pairing Method

125

999

SHORT MON

This message is displayed, if MON (Ma-
chine ON) output of control is short-cir-
cuited or overloaded.
This message is generated in EMG state.

This message causes
EMG state and loss
of reference point. It
can be canceled by
RESET.

1020

POSITION ERROR

This message is displayed, if the position
lag does not reach the value specified at
parameter within 5 seconds after the
interpolator has stopped. The above detec-
tion is executed in case of command G00
if parameter 1241 POSCHECK is 1, or in
case of feed movement in states G9 and
G61.

The message is can-
celed by RESET
key. In order to
repair the cause of
error, the input
offsets of the drives
must be zeroed.

1100

REFERENCE POINT t1

This message is displayed, if the reference
point switch has not been found within the
distance specified at parameter REFDIS
(or if it cannot stop within that distance).
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1100, 1110, 1120, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.

The message is can-
celed by RESET
key.

1110

1120

1130

1140

1150

1160

1170

1101

REFERENCE POINT t2

This message is displayed if it cannot run
off the switch within the distance
specified at parameter SWLENGTH.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1101, 1111, 1121, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.

The message is can-
celed by RESET
key.

1111

1121

1131

1141

1151

1171

Advertising