3.6

SETTING Screens

47

3.6.3 Screen of COMMON MACRO VARIABLES #500–#599

In the general displaying area
common macro variables
#500–#599 and their values can
be seen. These variables are not
vacated upon power-off or when
restoring automatic mode
(RESET), on the other hand by
switching to parameters, when
saving parameters they are saved
to the external device, and when
loading parameters the original
values are overwritten.
A highlighting bar can be moved
along the macro variables by
means of arrow keys up and
down. This highlighting bar

shows the variables to be edited. A new value can be given to the variable in the bottom line of
general displaying area. By terminating data input the new value is written in the variable.
Values can also be given to macro variables indirectly; By entering the code of another macro
variable (e.g.: #124) it registers the value of that variable. By entering #0 the macro variable is
vacated.

Actions of COMMON MACRO VARIABLES #500–#599 Screen

The following actions and action menus can be activated to the screen of COMMON MACRO

VARIABLES #500–#599 by pressing action menu key

:

Vacant
all

1

Zero
all

2

Exp

3

4

5

6

7

8

9

0

Vacant All Action Menu: When pressing the key the question CLEAR VACANT ALL?

can be seen in the bottom left part of general displaying area, together with Exec and
Cancel actions in the menu bars, the meaning of which is the usual. With Exec in effect
all macro variables are vacated (#0).

Zero All Action Menu: When pressing the key the question ZERO ALL? can be seen in the

bottom left part of general displaying area, together with Exec and Cancel actions n
the menu bar, the meaning of which is the usual. With Exec in effect all macro variables
are zeroed (0).

Exp Action: When pressing the key the exponent of the variable can be entered.