NCT Group NCT 990T User Manual

Page 82

Advertising
background image

7.2.4

Calibrating Tool Offset Sensor

82

Calibrating the Sensor to the Coordinate System of Chuck

The enclosed diagram beside shows the in-
terpretation of CONTACT parameters.

Calibrating in X direction

Turn an optional workpiece, leave the
workpiece in Z direction and read the ma-
chine position of X axis, indicated with
X

workp

on the diagram below.

Measure the workpiece diameter indicated
with D on the figure.
Execute an automatic tool length measure as
discussed in the previous chapter in X–
direction. Read the selected X offset register
value indicated with X

(–)

on the diagram.

Calculate and enter the value of parameter CONTACTX– with the help of the following
equation:

CONTACTX– = [X

(–)

– (X

workp

– D)]/2

In the above equation X position display is supposed to be in diameter.
The position of X+ button can also be defined by means of the above procedure

Calibrating in Z direction

Define the position of tool tip according to the chuck indicated with Z

chuck

on the diagram

below.
Execute an automatic tool length measurement as discussed in the previous chapter in Z–
direction. Read the selected Z offset register value indicated with Z

(–)

on the diagram. Calculate

and enter the value of parameter CONTACTZ– with the help of the following equation:

CONTACTZ– = Z

(–)

– Z

chuck

The position of Z+ button can also be defined by means of the above procedure.

Advertising
This manual is related to the following products: