NCT Group NCT 990T User Manual

Page 126

Advertising
background image

14.3

Listing of Global Messages

Error

Code

Message

Description

Canceling and Re-

pairing Method

126

1102

REFERENCE POINT t3

This message is displayed, if the zero
pulse has not been found after leaving the
reference switch within the distance spec-
ified at parameter SWSHIFT +

:

ZEROD-

IS.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1102, 1112, 1122, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.

The message is can-
celed by RESET
key.

1112

1122

1132

1142

1152

1162

1172

1103

REFERENCE POINT t4

If during the reference point return zero
pulse is found, the axis changes its direc-
tion and searches for it again in the new
direction at a lower speed. If this time it
cannot find the zero pulse within 1000 in-
crements, this message is displayed.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1103, 1113, 1123, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.

The message is can-
celed by RESET
key.

1113

1123

1133

1143

1153

1163

1173

1104

REFERENCE POINT t5

This message is displayed, if during the
reference point return zero pulse is found
after running off the switch within the dis-
tance specified at parameter SWSHIFT +

3

ZERODIS.

Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1104, 1114, 1124, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.

The message is can-
celed by RESET
key.

1114

1124

1134

1144

1154

1164

1174