14.3

Listing of Global Messages

Error

Code

Message

Description

Canceling and Re-

pairing Method

131

3018

,A IN G2, G3

If in circular interpolation block (G2, G3)
angle (,A) has been programmed.

The message is can-
celed by RESET
key.

3019

D O M I N A T O R C O N -
STANT=0

If in 3D radius compensation calculation
the value of dominator constant is 0.

The message is can-
celed by RESET
key.

3020

DATA DEFINITION ER-
ROR G33,G34

If in block G33, G34
more than 2 axes have been programmed,
or
both E and F are filled out, or
the thread lead is 0, or
,C or ,R has been programmed.

The message is can-
celed by RESET
key.

3021

G51 IN G33

If in block G33 scaling (G51) is on.

The message is can-
celed by RESET
key.

3022

DIVIDE BY 0 IN G33

If G33 has been programmed and
value E is less than or equal with 0, or
the pulse number of spindle encoder on
parameter 5023 ENCODERS1 is 0.

The message is can-
celed by RESET
key.

3023

DATA DEFINITION ER-
ROR G26

In block G26 an address not interpreted
has been specified or there is a value
specification error at an interpreted ad-
dress.

The message is can-
celed by RESET
key.

3024

ERRONEOUS P VALUE IN
G96

If in block G96 (programming constant
surface speed) value P is not 1...9.

The message is can-
celed by RESET
key.

3025

DEFINITION ERROR S

If programmed spindle revolution (S) is
greater than 65000 or
negative or
in canned cycles G84.2, G84.3 equals to
0.

The message is can-
celed by RESET
key.

3026

DEFINITION ERROR G10
L3

If in block G10 L3 (filling up the life time
table) P or L are in one block under ad-
dress T, H or D or other address was pro-
grammed.

The message is can-
celed by RESET
key.

3027

DEFINIT. ERROR T IN
G10 L3

If in block G10 L3 (filling up the life time
table) address T is defined without a
group being referred to.

The message is can-
celed by RESET
key.

3028

MORE TOOLS IN G10 L3

If in block G10 L3 (filling up life time ta-
ble) the number of tools within a group
exceeds the maximum value registered on
parameter 1181 GROUPNUM.

The message is can-
celed by RESET
key.