14.3

Listing of Global Messages

Error

Code

Message

Description

Canceling and Re-

pairing Method

139

3123

3124

3125

3126

3127

3500

PROGRAM EDITED

This message is displayed, if program se-
lected for automatic execution is edited in
automatic mode, or
if program selected for manual data input
execution is edited in MDI mode,
meanwhile START is pressed.

The message is can-
celed by RESET
key.
The program can be
started if the EDIT
screen is closed after
terminating editing.

3502

BAD BAUD RATE VALUE

If not standard baud rate value or a baud
rate that cannot be interpreted by control
is set at parameter 2002 BAUD RATE. It
is displayed in DNC mode. The values
interpreted by the control are listed in the
description of parameters.

The message is can-
celed by RESET
key.

3503

SERIAL BUFFER FULL

If the serial buffer has been overrun in the
course of DNC machining.

The message is can-
celed by RESET
key.
Data transfer must be
restarted.

3504

TOOL PLACE TABLE BAD

If NC finds the check sum of the tool pot
table false.

The message is can-
celed by RESET
key.
Tool pot table must
be reorganized.

3505

N O T

E X I S T I N G

PROGRAM

If a program had been selected for auto-
matic or MDI execution, than the program
was deleted and without selecting a new
program START is pressed in automatic
or MDI mode.

The message is can-
celed by RESET
key.

3507

OVERWRITE (Y/N)

If the program being executed loads pro-
gram to the control memory by means of
command DPRNT, with the number of
which a program has already been regis-
tered in the directory.

If the old program is
to be overwritten key
Y must be pressed,
otherwise key N or
RESET.

Advertising