Cp3 bt26 – National CP3BT26 User Manual

Page 135

Advertising
background image

135

www.national.com

CP3

BT26

INTERNAL

If the Internal function is enabled, the CANTX
and CANRX pins of the CAN module are inter-
nally connected to each other. This feature
can be used in conjunction with the LOOP-
BACK mode. This means that the CAN mod-
ule can receive its own sent messages
without connecting an external transceiver
chip to the CANTX and CANRX pins; it allows
software to run real stand-alone tests without
any peripheral devices.
0 – Normal mode.
1 – Internal mode.

DIAGEN

The Diagnostic Enable bit globally enables or
disables the special diagnostic features of the
CAN module. This includes the following func-
tions:

LO (Listen Only).

IGNACK (Ignore Acknowledge).

LOOPBACK (Loopback).

INTERNAL (Internal Loopback).

Write access to hidden receive buffer.

0 – Normal mode.
1 – Diagnostic features enabled.

EIT

The Error Interrupt Type bit configures when
the Error Interrupt Pending Bit (CIPND.EIP-
ND) is set and an error interrupt is generated
if enabled by the Error Interrupt Enable
(CIEN.EIEN).
0 – The EIPND bit is set on every error on the

CAN bus.

1 – The EIPND bit is set only if the error state

(CSTPND.NS) changes as a result of in-
crementing either the receive or transmit
error counter.

19.10.7 CAN Timing Register (CTIM)

The Can Timing Register (CTIM) defines the configuration
of the Bit Time Logic (BTL).

PSC

The Prescaler Configuration field specifies
the CAN prescaler. The settings are shown in
Table 57

SJW

The Synchronization Jump Width field speci-
fies the Synchronization Jump Width, which
can be programmed between 1 and 4 time
quanta (see Table 58).

Note: The settings of SJW must be configured to be small-
er or equal to TSEG1 and TSEG2

15

9

8

7

6

3

2

0

PSC

SJW

TSEG1

TSEG2

0

R/W

Table 57

CAN Prescaler Settings

PSC6:0

Prescaler

000000

2

000001

3

000010

4

000011

5

000100

6

:

:

1111101

127

1111110

128

1111111

128

Table 58

SJW Settings

SJW

Synchronization Jump

Width (SJW)

00

1 time quantum

01

2 time quanta

10

3 time quanta

11

4 time quanta

Advertising