178

CP3BT26

23.3

SLAVE MODE

In Slave mode, the MSK pin is an input for the shift clock
MSK. MDIDO is placed in TRI-STATE mode when MWCS is
inactive. Data transfer is enabled when MWCS is active.

The slave starts driving MDIDO when MWCS is active. The
most significant bit (lower byte in 8-bit mode or upper byte
in 16-bit mode) is output onto the MDIDO pin first. After
eight or sixteen clocks (depending on the selected mode),
the data transfer is completed.

If a new shift process starts before MWDAT was written, i.e.,
while MWDAT does not contain any valid data, and the
ECHO bit is set, the data received from MDODI is transmit-
ted on MDIDO in addition to being shifted to MWDAT. If the
ECHO bit is clear, the data transmitted on MDIDO is the
data held in the MWDAT register, regardless of its validity.
The master may negate the MWCS signal to synchronize
the bit count between the master and the slave. In the case
that the slave is the only slave in the system, MWCS can be
tied to ground.

23.4

INTERRUPT GENERATION

Interrupts may be enabled for any of the conditions shown
in Table 73.

Figure 89 illustrates the interrupt generation logic of this
module.

Figure 89.

MWSPI Interrupts

Table 73

Microwire Interrupt Trigger Condition

Condition

Status

Bit in the
MWSTAT

Register

Interrupt

Enable Bit

in the

MWCTRL1

Register

Description

Not Busy

BSY

EIW

The shifter is ready
for the next data
transfer sequence.

Read

Buffer Full

RBF

EIR

The read buffer is
full and waiting to be
unloaded.

Overrun

OVF

EIO

A new data transfer
sequence started
while both the shifter
and the read buffer
were full.

MWSPI
Interrupt

OVR = 1

EIO

RBF = 1

EIR

BSY = 0

EIW

DS073

Advertising