Cp3bt26 – National CP3BT26 User Manual

Page 84

Advertising
background image

www.national.com

84

CP3BT26

16.5.1

ADC Global Configuration Register (ADCGCR)

The ADCGCR register controls the basic operation of the in-
terface. The CPU bus master has read/write access to the
ADCGCR register. After reset this register is set to 0000h.

CLKEN

The Clock Enable bit controls whether the
ADC module is running. When this bit is clear,
all ADC clocks are disabled, the ADC analog
circuits are in a low-power state, and ADC
registers (other than the ADCGCR and AG-
CACR registers) are not writeable. Clearing
this bit reinitializes the ADC state machine
and cancels any pending trigger event. When
this bit is set, the ADC clocks are enabled and
the ADC analog circuits are powered up. The
converter is operational within 0.25 µs of be-
ing enabled.
0 – ADC disabled.
1 – ADC enabled.

ADCIN

The ADCIN bit selects the source of the ADC
input. When the bit is clear, the source is the
8-channel Input Multiplexer. When the bit is
set, the source is the ADCIN pin.
0 – ADC input is from 8-channel multiplexer.
1 – ADC input is from ADCIN pin.

DIFF

The Differential Operation Mode bit and the
MUX_CFG field configure the analog circuits
of the ADC module. When this bit is clear, the
ADC module operates in single-ended mode.
When this bit is set, the ADC operates in dif-
ferential mode. See Table 35 .
0 – Single-ended mode.
1 – Differential mode.

MUX_CFG

The Multiplexer Configuration field and the
DIFF bit configure the analog circuits of the
ADC module, as shown in Table 35.

For best noise immunity in touchscreen appli-
cations, channel 2 should be used for sam-
pling the X plate voltage, and channel 1
should be used for sampling the Y plate volt-
age.

TOUCH_CFG The Touchscreen Configuration field controls

the configuration of the low-ohmic drivers for
the TSX+, TSX-, TSY+, and TSY- signals, as
shown in Table 36. When TOUCH_CFG is
101b, the pen-down detector is enabled. The
output of the pen-down detector is visible to
software in the PEN_DOWN bit of the AD-
SRESLT register, and it is ORed with the
Done signal to generate the wake-up signal
WUI30 passed to the MIWU unit.

8

7

6

5

4

3

2

1

0

TOUCH_CFG

MUX_CFG

DIFF ADCIN CLKEN

15

14

13

12

11 10

9

MUXOUTEN INTEN Res.

NREF_CFG

PREF_CFG

Table 35

MUX_CFG Operation

MUX_CFG

Channel

Selected,

(DIFF = 0)

Channels

Selected

(DIFF = 1)

+

-

000

0

0

1

001

1

1

0

010

2

2

3

011

3

3

2

100

4

4

5

101

5

5

4

110

6

6

7

111

7

7

6

Table 36

TOUCH_CFG Modes

TOUCH_CFG

ADC0/TSX+

ADC1/TSY+

ADC2/TSX-

ADC3/TSY-

Mode

000

Inactive

Inactive

Inactive

Inactive

None

001

Inactive

Driven High

Inactive

Driven Low

Sample Y

010

Driven High

Inactive

Driven Low

Inactive

Sample X

011

Driven High

Inactive

Inactive

Driven Low

Sample Z (1),

Pre-Pen Down

100

Inactive

Driven High

Driven Low

Inactive

Sample Z (2)

101

Weakly Pulled High

Inactive

Inactive

Driven Low

Pen-Down Detect

11X

Inactive

Inactive

Inactive

inactive

Reserved