3 usb controller registers, Usb controller registers, Cp3 bt26 – National CP3BT26 User Manual

Page 93

Advertising
background image

93

www.national.com

CP3

BT26

Receive Endpoint FIFO Operation (RXFIFO1, RXFIFO2,

RXFIFO3)

The Receive FIFOs for endpoints 2, 4, and 6 support bulk,
interrupt, and isochronous USB packet transfers larger than
the actual FIFO size. If the packet length exceeds the FIFO
size, software must read the FIFO contents while the USB
packet is being received on the bus. Figure 32 shows the
detailed behavior of receive FIFOs.

Figure 32.

Receive FIFO Operation

RFnS

The Receive FIFO n Size is the total number
of bytes available within the FIFO.

RXRP

The Receive Read Pointer is incremented
with every read by software from the receive
FIFO. This pointer wraps around to zero if
RFnS is reached. RXRP is never incremented
beyond the value of RXWP. If an attempt is
made to read more bytes than are actually
available (FIFO underrun), the last byte is
read repeatedly.

RXWP

The Receive Write Pointer is incremented ev-
ery time the Endpoint Controller writes to the
receive FIFO. This pointer wraps around to
zero if RFnS is reached. An overrun condition
occurs if RXRP equals RXWP and an attempt
is made to write an additional byte.

RXFL

The Receive FIFO Level indicates how many
more bytes can be received until an overrun
condition occurs with the next write to the
FIFO. A FIFO warning is issued if RXFL de-
creases to a specific value. The respective
WARNn bit in the FWR register is set if RXFL
is equal to or less than the number specified
by the RFWL bit in the RXCn register.

RCOUNT

The Receive FIFO Count indicates how many
bytes can be read from the receive FIFO. This
value is accessible by software via the RXSn
register.

18.3

USB CONTROLLER REGISTERS

The CR16 USB node has a set of memory-mapped regis-
ters that can be read/written from the CPU bus to control the
USB interface. Some register bits are reserved; reading
from these bits returns undefined data. Reserved register
bits must always be written with 0.

FLUSH (Resets RXRP and RXWP)

RXRP

RCOUNT = RXWP

-

RXRF

RXWP

RXFL = RXRP

-

RXWP (= RFnS

-

RCOUNT)

RX FIFO n

0X0

RFnS

-

1

+

+

+

DS052

Table 40

USB Controller Registers

Name

Address

Description

MCNTRL

FF FD80h

Main Control Register

NFSR

FF FD8Ah

Node Functional State

Register

MAEV

FF FD8Ch

Main Event Register

ALTEV

FF FD90h

Alternate Event

Register

MAMSK

FF FD8Eh

Main Mask Register

ALTMSK

FF FD92h

Alternate Mask

Register

TXEV

FF FD94h

Transmit Event

Register

TXMSK

FF FD96h

Transmit Mask

Register

RXEV

FF FD98h

Receive Event

Register

RXMSK

FF FD9Ah

Receive Mask

Register

NAKEV

FF FD9Ch

NAK Event Register

NAKMSK

FF FD9Eh

NAK Mask Register

FWEV

FF FDA0h

FIFO Warning Event

Register

FWMSK

FF FDA2h

FIFO Warning Mask

Register

FNH

FF FDA4h

Frame Number High

Byte Register

FNL

FF FDA6h

Frame Number Low

Byte Register

FAR

FF FD88h

Function Address

Register

DMACNTRL

FF FDA8h

DMA Control Register

DMAEV

FF FDAAh

DMA Event Register

DMAMSK

FF FDACh

DMA Mask Register

MIR

FF FDAEh

Mirror Register

DMACNT

FF FDB0h

DMA Count Register

DMAERR

FF FDB2h

DMA Error Register

Advertising