Dynamic Acquisition

When performing dynamic acquisition with the NI 654X/655X, the source
generating the signals needs a matched source impedance as close to 50

as

possible to minimize signal reflections and maintain optimal signal quality.
Figure 7 shows a diagram of a dynamic acquisition system using the NI 655X
as an example.

Figure 7. Dynamic Acquisition Functional Diagram

Note

NI digital waveform generator/analyzers have various input

impedance settings, as shown in the following table.

Refer to the NI Digital Waveform Generator/Analyzer Help for more
information about signal termination.

Table 3. Supported Impedance Settings

Device

Supported Input Impedance

NI 654X

10 k

NI 655X

50

or 10 k

NI 656X

*

100

for channels configured for

LVDS operation; 10 k

for channels

configured for single-ended operation

*

NI 656X cables use 100

differential impedance rather than 50

single-ended

impedance.

NI 655

X

NI CB-2162

R

S

R

T

Peripheral
Device

50 Cable