Performance mode settings, Signal (part) flow, Parameters – Roland XV-5080. User Manual

Page 111: Signal (part) flow parameters

Advertising
background image

111

Chapter 3 Selecting Output Jacks

Chap.3

Performance Mode Settings

Signal (PART) Flow

fig.03-002.e

Parameters

The parameters related to Part output settings are shown
below.

PERFORMANCE Effects General page
([PERFORM] - [F6 (Effects)] - [F1
(General)])

Sets the output destination and level for the selected Part, as
well as its send level with respect to the Chorus and Reverb.

Part Output Assign

Available Settings:

MFX:

The Part is sent into the Multi-effects. Its output

destination is determined by the Multi-effects output

settings.

A–D:

The Part is sent to the selected pair of OUTPUT A–D

jacks.

1–8:

The Part is sent to the INDIVIDUAL OUTPUT jacks 1–8.

PAT:

The Part’s output destination is determined by the

settings of the Patch or Rhythm Set assigned to the Part.

Part Output MFX Select

Available Settings:

A–C

Selects which of the three Multi-effects is to be used.

Part Dry Send Level

Range:

0–127

Sets the level of the signal to be sent to the OUTPUT jacks,
which is determined by Part Output Assign.

B

A

C

D

CHO

PART

OUTPUT B

OUTPUT C

OUTPUT D

REV

Output Assign

M-FX
Output Assign

Chorus
Output Assign

Reverb
Output Assign

OUTPUT A

M-FX A

M-FX B

M-FX C

Advertising