Accessory parts and Parts to be procured locally

H

Accessory parts

H

Parts to be procured locally

Connecting pipe (Liquid side)
(6.35mm (diam.), Nominal (diam.) 1/4” thick 0.8mm)
RAV-SM560UT-E, RAV-SM560AT-E

(9.52mm (diam.), Nominal (diam.) 3/8” thick 0.8mm)
RAV-SM800UT-E, RAV-SM800AT-E

Connecting pipe (Gas side)
(12.7mm (diam.), Nominal (diam.) 1/2” thick 0.8mm)
RAV-SM560UT-E, RAV-SM560AT-E

(15.9mm (diam.), Nominal (diam.) 5/8” thick 1.0mm)
RAV-SM800UT-E, RAV-SM800AT-E

Power supply cord
2.5mm² (H07RN-F or 245IEC66) or 3.5mm² (AWG-12)

Connecting cable
H07RN-F or 245IEC66 (1.5mm² or more)

Thermal insulation for refrigerant pipe
(10mm or more, thermal insulating foam polyethylene)

Thermal insulation for drain pipe
(10mm or more, foam polyethylene)

Drain pipe (Outer 26mm (diam.))

Tapes

Grounding cable (2.0mm (diam.) or more)

Part name

Installation
Manual

Heat insulating
pipe

Installation
pattern

Installation
gauge

Pattern fixing
screw

Heat insulator

Q’ty

1

2

1

2

4

1

Shape

This

manual

——

M5 x 16L

Usage

(Be sure to hand over to customers)

For heat insulation of pipe
connecting section

For confirmation of ceiling opening
and main unit position

For positioning of ceiling position
(united with installation pattern)

For attach the installation pattern

For heat insulation of drain
connecting section

Part name

Washer

Hose band

Flexible hose

Heat insulator

Owner’s
Manual

Q’ty

8

1

1

1

1

Shape

Usage

For hanging-down unit

For connecting drain pipe

For adjusting core-out of drain
pipe

For sealing of wire connecting port

(Be sure to hand over to customers)

<Separate sold parts>