DRAIN PIPING WORK

Piping and Drain Hose Installation

In case of right-side exit

• Cut out the knockout portion by the slits with a knife

or pair of wire cutters as necessary.

Slit
(Body right)

Slit
(Body right)

465mm

365mm

Liquid side

Gas side

Outward form
of indoor unit

(To the front of the flare)

R 30mm

43mm

Use the handle of a screwdriver, etc.

80˚

In case of downward pipe exit

• Cut out the knockout portion by the slits with a knife

or pair of wire cutters as necessary.

Piping via left-hand connection

Bend the connecting pipe so that it is laid within 43mm above the wall surface. If the connecting pipe is laid
exceeding 43mm above the wall surface, the indoor unit could be unstable when set on the wall. When bending the
connecting pipes, always use a suitable bending tool to avoid damaging the pipes.

Bend the connection pipe within a radius of 30mm.

To connect the pipe after installation of unit (figure)

NOTE :

If the pipe is bent incorrectly, the indoor unit could be unstable on the wall.

After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and
insulate as necessary.