Installation procedure, Caution, Installation diagram of indoor unit – Toshiba RAM-SM560BT-E User Manual

Page 97: Mounting the installation plate

Advertising
background image

94

2

INSTALLATION PROCEDURE

Installation Diagram of Indoor Unit

Air filter

Min. 6 mm thick heat resisting polyethylene foam

Bottom

Right

Rear left

Rear

Left

Cut the piping hole
sloped slightly

Wall

For rear left and side pipe exit

Do not allow the drain hose to sag.

Make sure to run the drain hose
sloped downward.

The auxiliary piping can be connected
the left, rear left, rear, right or bottom.

Insulate the refrigerant pipes
separately with insulation, not together.

Insert the cushion between the
indoor unit and wall, and lift indoor
unit to make work easier.

Hook

1 Installation
plate

Hook

170mm

or more

65mm or more

170mm

or more

Pipe
insulation

Mounting the Installation Plate

For installation of the indoor unit,
use the paper template included.

When the installation plate is directly mounted on the wall

1. Securely fix the installation plate to the wall by screwing it through the upper and lower fixing holes.

2. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in

the above figure.

3. Attach the installation plate horizontally to the wall.

CAUTION

When installing the installation plate with mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal injury and property damage.

Ø5mm hole

Clip anchor
(local parts)

Mounting screw
Ø4 x 25mm

Anchor bolt

Projection
15mm or less

Indoor unit

Weight

Installation
plate

Pipe hole

Mounting screw

Mounting screw

Pipe hole

Thread

Hook

Hook

Hook

0

80 100

100mm

100mm

180

Indoor unit

55

65

170

120

R

A

V

-SM560KR

T

-E

R

A

V

-SM800KR

T

-E

Advertising