FILE NO. SVM-03008

6. REFRIGERANT CYCLE DIAGRAM

6-1. Refrigerant Cycle Diagram

Note :

The maximum length of the pipe for this air conditioner is 15 m. The additional charging of refrigerant is
unnecessary because this air conditioner is designed with charge-less specification.

Deoxidized copper pipe

NOTE :

Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

INDOOR UNIT

T1

TO

Temp. measurement

Indoor heat

exchanger

Cross flow fan

Deoxidized copper pipe
Outer dia. : 6.35 mm
Thickness : 0.8 mm

Sectional shape
of heat insulator

Allowable height

dif

ference : 10m

Allowable pipe length

Max. : 15 m

P

Pressure measurement
Gauge attaching port
Vacuum pump connecting port

Strainer

Pulse modulating
valve at liquid side
(SEV16RC3)

1.5 x 200

s

1.5 x 200

s

TD

4-way valve
(CHV-0213)

Compressor
DA91A1F-45F

TS

T2

Outdoor heat

exchanger

Split capillary

Temp. measurement

Propeller fan

Refrigerant amount : 0.9 kg

OUTDOOR UNIT

Muffler

Muffler

TE

Outer dia. : 9.52 mm
Thickness : 0.8 mm