Toshiba RAS-13UAV-E2 User Manual

Page 5

Advertising
background image

– 4 –

FILE NO. SVM-03008

1-2. Operation Characteristic Curve

<Cooling>

<Heating>

7

6

5

4

3

2

1

0

Current (A)

Compressor speed (rps)

0

20

40

60

80

100

Conditions

Indoor : DB 27

°

C/WB 19

°

C

Outdoor : DB 35

°

C

Air flow : High
Pipe length : 5m
230V

7

6

5

4

3

2

1

0

Current (A)

Compressor speed (rps)

0

20

40

60

80

100

Conditions

Indoor : DB 20

°

C

Outdoor : DB 7

°

C/WB 6

°

C

Air flow : High
Pipe length : 5m
230V

1-3. Capacity Variation Ratio According to Temperature

<Cooling>

<Heating>

120

110

100

90

80

70

60

50

40

30

20

10

0

10

9

8

7

6

5

4

3

2

1 0 1 2 3 4 5 6 7 8 9 10

Capacity r

a

tio (%)

Outdoor temp. (

°

C)

Conditions

Indoor : DB 20

°

C

Indoor air flow : High
Pipe length : 5m

*

Capacity ratio : 100% = 3.5 kW

105

100

95

90

85

80

75

70

65

60

55

50

32

34

36

38

40

42

33

35

37

39

41

43

Outdoor temp. (

°

C)

Capacity ratio (%)

Conditions

Indoor : DB27

°

C/WB19

°

C

Indoor air flow : High
Pipe length 5m

Current Limited Start