Caution, 2. indoor unit – Toshiba RAS-13UAV-E2 User Manual

Page 44

Advertising
background image

– 43 –

FILE NO. SVM-03008

9-2. Indoor Unit

9-2-1. Installation place

•

A place which provides the spaces around the
indoor unit as shown in the above diagram.

•

A place where there is no obstacle near the air inlet
and outlet.

•

A place that allows easy installation of the piping to
the outdoor unit.

•

A place which allows the front panel to be opened.

•

The indoor unit shall be installed as top of the
indoor unit comes to at least 2 m height.
Also it must be avoided to put anything on the top of
the indoor unit.

CAUTION

•

Direct sunlight to the indoor unit’s wireless
receiver should be avoided.

•

The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner’s manual.)

<Remote controller>

•

A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.

•

Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.

•

Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)

•

The location of the remote control should be
determined as shown below.

Fig. 9-2-1

(Top view)

Indoor unit

* : Axial distance

Reception
range

Reception
range

Remote
control

Remote
control

(Side view)

9-2-2. Cutting a hole and mounting installation

plate

<Cutting a hole>

When installing the refrigerant pipes from the rear.

Fig. 9-2-2

1. After determining the pipe hole position on the

mounting plate (

A

), drill the pipe hole (

∅

65 mm) at

a slight downward slant to the outdoor side.

NOTE:

•

When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.

<Mounting the installation plate>

For installation of the indoor unit, use the paper pattern
on the back.

Fig. 9-2-3

Indoor unit

5 m

5 m

45

°

45

°

75

°

* 7 m

7 m

65 mm

100 mm

The center of the pipe
hole is above the arrow.

Pipe hole

Hook

Anchor bolt holes

2 m or more fr

om floor

62

85

82.5

170

Pipe
hole

Pipe hole

Indoor unit

Thread

Weight

Hook

7

Mounting screw

Hook

1

Installation
plate

Advertising