FILE NO. SVM-03008

– 36 –

8-7. Hi POWER Mode ([Hi POWER] button

on the remote control is pushed.)

When [Hi POWER] button is pushed while the indoor
unit is in Auto, Cooling or Heating operation, Hi
POWER mark is indicated on the display of the remote
control and the unit operates as follows.

(1) Automatic operation

The indoor unit operates in according to the
current operation.

(2) Cooling operation

The preset temperature drops 1

°

C.

(The value of the preset temperature on the
remote controller does not change.)

If the difference between the preset tempera-
ture and the room temperature is big, the
horizontal louver moves to the Hi POWER
position automatically. Then when the differ-
ence between them gets smaller, the horizontal
louver returns automatically.

(3) Heating operation

The preset temperature increases 2

°

C. (The

value of the preset temperature on the remote
control does not change.)

If the difference between the preset tempera-
ture and the room temperature is big, the
horizontal louver moves to the Hi POWER
position automatically. Then when the differ-
ence between them gets smaller, the horizontal
louver returns automatically.

(4) The Hi POWER mode can not be set in Dry or Fan

only operation.