9-1-1. Installation Diagram of Indoor and Outdoor Units

Shield
pipe

Air filt

er

Hoo

k

Hook

(Attac

h to the fr

ont panel)

65 mm or more

1

Installation

plate

170 m

m

or m

ore

170 m

m

or m

ore

For the rear left and left
piping

Insert the cushion between
the indoor unit and wall, and
lift the indoor unit for better
operation.

Wall

Insulate the refrigerant
pipes separately with
insulation, not together.

6 mm thick heat resisting
polyethylene foam

50 mm or more

from wall

Vinyl tape Apply
after carrying out
a drainage test

Extension
drain hose
(Option:
RB–821SW)

200 mm or more

600 mm or more

100 m

m or m

ore

from

wall

Saddle

Do not allow the drain hose
to get slack.

Make sure to run the drain
hose sloped downward.

Cut the piping
hole sloped
slightly

Left

Rear
left

Right

Rear right

Bottom
right

Bottom left

The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right
or bottom left.

250 m

m or m

ore

from

wall

6

Purifying filter

5

Zeolite filter

Before installing the
wireless remote control

With the remote control cover
open, load the batteries supplied
correctly, observing their polarity.

2

Wireless remote control

3

Batteries

Cover

2

Wireless remote control

8

Flat head wood screw

4

Remote control holder

As show in the figure, hang
power cord and connecting
cable downward, and take out it
along piping connection port.

Fig. 9-1-1