2. outdoor unit (inverter assembly), Micr o-computer block dia gram – Toshiba RAS-13UAV-E2 User Manual

Page 22

Advertising
background image

– 21 –

FILE NO. SVM-03008

7-2. Outdoor Unit (Inverter Assembly)

220

−

240 V

50/60 Hz

MICR

O-COMPUTER BLOCK DIA

GRAM

Over current

sensor

Driver circuit

of P.M.V.

Over current

sensor

Heat exchanger

temp.sensor

Suction temp.

sensor

Outdoor air

temp. sensor

Discharge

temp. sensor

Inddor unit

send/receive

circuit

Relay

circuit

Noise

Filter

Converter

(AC

→

DC)

Clock

frequency

16MHz

High Power

factor Correction

circuit

Input current

sensor

Rotor position

detect circuit

Rotor position

detect circuit

•

PWM synthesis function

•

Input current release control

•

IGBT over-current detect control

•

Outdoor fan control

•

High power factor correction control

•

Inverter output frequency control

•

A/D converter function

•

P.M.V. control

•

Discharge temp. control

•

4-way valve control

•

Signal communication to indoor unit

P.M.V

: Pulse Modulating Valve

M.C.U

: Micro Control Unit

M.C.U

For INDOOR UNIT

4-way valve

P.M.V.

Inverter

(DC

→

AC)

Over current

detect circuit

Gate drive

circuit

Gate drive

circuit

Over current

sensor

Inverter

(DC

→

AC)

Outdoor

Fan motor

Compressor

MCC813 (P

.C.B)

OUTDOOR UNIT