Xantrex Technology PV225S-480-P User Manual

Page 69

Advertising
background image

PC Communications

152606

3–21

Establishing a POTS Connection

To connect a personal computer using the POTS Connection:

1.

Ensure the personal computer to be used has a 56K modem installed.

2.

Open the Communications Enclosure.

3.

Plug the local phone line into the RJ11 port on the SA2 Surge Arrestor
marked "U

NPROTECTED

".

4.

Install the GUI Software following the instructions in the PV225S 225 kW
Grid-Tied Photovoltaic Inverter Operation and Maintenance Manual.

5.

Use a Terminal Emulation program on the PC to access the modem.

See the GUI Help Menu "Communication by Modem" for instructions on
setting up the Terminal Emulation program on the computer. See also,
"Connect to Telephone Number" and "Connect to Remote Inverter by
Modem" for additional information.

6.

Use the GUI to setup the connection information.

a) From the GUI Main page, click on <T

OOLS

>

b) Click on the inverter icon for the inverter to be setup.

c) Click on the <I

NVERTER

D

ATA

>

d) Click on the <C

ONNECTION

> tab.

e) Fill out the information required on the <G

ENERAL

> page, the

<T

ELEPHONE

F

AULT

C

ONFIGURATION

> page, and the <T

ELEPHONE

C

ONFIGURATION

> page.

Important:

A direct analog phone line to the local phone service is required to use this

feature. The phone line used for PV225S communication cannot be routed through a
Private Branch Exchange (PBX) unless an analog PBX card is used.

Figure 3-20 Telephone Cable Routing

MultiTech 56K
Modem

SA2 Surge Arrestor