ZyXEL Communications omni.net Plus User Manual

Page 159

Advertising
background image

Technical Reference for ZyXEL omni.net series

B-7

All the Following Commands Require a 'AT' Prefix

S Com.

bit

dec

hex

Function and description

+Def./Ref.

S20=

dec

hex

DTE port speed (bps).

Auto detected from AT Command.

+003

0

0

230400

bps

1

1

115200

bps

3

3

57600

bps

4

4

38400

bps

5

5

19200

bps

9

9

9600

bps

11

B

4800

bps

12

C

2400

bps

13

D

1200

bps

14

E

460800

bps

S21=

bit

dec

Hex

Bit mapped register

+178

0-1

For omni.net LCD+M only.

3 0 0 DSR

always

On.

&S0

8

8

According to CCITT (see also S44b4, S41b5).

&S1

4 0 0 CD

always

On.

&C0

16

10

CD tracks presence of data connection (see also S38b3).

&C1

5

0

0

CTS follows RTS, in synchronous mode.

&R0

32

20

Ignore RTS (CTS always On), in synchronous mode

&R1

6-7

0

0

Assume DTR always On.

&D0

64

40

108.1, DTR Off-On transition causes dial of the default
number.

&D1

128

80

108.2 Data Terminal Ready, DTR Off causes the omni.net to
hang up and return to command state.

&D2

192

C0

108.2, DTR Off causes the omni.net to hang up and reset
the omni.net to profile #0 after DTR dropped.

&D3

Advertising