Technical Reference for ZyXEL omni.net series

B-12

All the Following Commands Require a 'AT' Prefix

S Com.

bit

dec

hex

Function and description

+Def./Ref.

64

40

Sending Low Layer Compatibility information for ISDN data
call.

7

0 (*)

0

Not send Low Layer Compatibility information for POTS port
1.

128

80

Sending Low Layer Compatibility information for POTS port
1.

S82=

dec

ISDN

B-channel

protocol.

Bn

60

V.120

64000

61

V.120

56000

62

X.75 64000 Transparent

63

X.75 56000 Transparent

64

X.75 64000 T.70

65

X.75 56000 T.70

70

X.75 64000 BTX

71

X.75 56000 BTX

72

V.110

64000

73

V.110

56000

74

PPP

async

to

sync

64K

75

PPP

async

to

sync

56K

76

SLIP to sync HDLC conversion 64K.

77

SLIP to sync HDLC conversion 56K.

S83= bit dec

hex

Bit-mapped

register

+000

2 0 0 ISDN

without

V.42bis.

&K00

4

4

ISDN with V.42bis if applicable.

&K44

4-5

0

0

ATDs, ATDPs, and ATDTs is mapped to ATDBs.

&O0

32

20(*) ATDs, ATDPs, and ATDTs is mapped to ATDIs.

&O2

48

30

ATDs, ATDPs, and ATDTs is mapped to ATDAs.

&O3

7

0

0 (*)

ISDN data call using normal Bearer Service.

(for USA only)

128

80

ISDN data call using Voice Bearer Service.