Section 1. Features and Specifications
Additional Characteristics

20

Operating Manual for XPD Series Power Supply

Additional Characteristics

Remote Programming and Monitoring

Over Temperature Protection (OTP)

Unit latches off when T > rated maximum.
Auto restart when cool

OVP Control

Adjustable on front panel single turn control.
110% setting 5% of rated output

Switching Frequency

125 kHz (250 kHz output ripple)

Output Hold-up Time

10 ms @120 Vac input

Insulation Resistance

Input to chassis: >30 M ohm, with 500 Vdc
Output to chassis: >20 M ohm, with
1000 Vdc

Isolation Voltage

Input to output: 1350 Vac

Remote S/D and Interlock

1

5–15 V signal or TTL-compatible output,
selectable logic. TTL input impedance: 2 k
(in series with one diode drop)

Remote Analog Programming (Full
Scale Input)

Voltage and current programming inputs
(source must be floating): 0-10 V voltage
sources.
Input impedance (V and I): 20 k

Remote Monitoring

Output voltage and current: 0-10 V
Output impedance (V and I): approximately
221 ohm; output short circuit current:
approximately 20 mA (load must be floating)

Remote Programming and Monitoring
Accuracy

1% of full scale output for the default range

Maximum Remote Sense Line Drop
Compensation

7.5 V model: 3 V/line;

2

18-120 V models: 5 V/line

2

Optional Digital Control

RS-232, GPIB interfaces

1. Isolated from power supply output and chassis to 500 V.
2. Line drop must be deduced from supply maximum output.