Section 4. Remote Operation

Status Flags

Release A

51

Status Flags

The power supply has 5 status flags to indicate the operating state. The S/D LED on
the front panel, and 4 LEDs visible from the top of the unit. The flags, listed in order
from front to rear, are OTP, OVP, SNS-PROT and AC-FAIL.

In the event of one of the flags being tripped, the flag is raised along with S/D flag
on the front panel. An S/D flag with none of the other 4 flags indicates remote
shutdown (J210,1and 2).

OTP

Over-temperature protection indicates a supply shutdown due to
over-temperature triggering the OTP circuitry. The unit has an
auto-restart feature when the supply’s temperature is within the correct
temperature range again.

OVP

Over-voltage protection indicates shutdown due to output voltage
exceeding the threshold preset using the OVP trimpot on the front
panel.

SNS-PROT

Sense line protection indicates a shutdown due to a voltage drop on the
load lines exceeding 5 V per line (3 V per line for 7.5 V model) in remote
sense mode. This condition may also occur if the unit is operated
without the J207 default sense line connector.

AC-FAIL

AC fail indicates a mains V

ac

input out of the supply’s specified range

(i.e. below 85 V

ac

or over 264 V

ac).