Configuring Multiple Supplies for Series Operation (Voltage Mode Only)

Connect power supplies in series to obtain a single output supply with higher output
voltage. Connect the negative (–) terminal of one supply to the positive (+) terminal
of the next supply. The total voltage available is the sum of the maximum voltages
of each supply (add voltmeter readings). The maximum current available to the load
is equal to the current of the lowest rated supply in the series. See

Figure 3.2

for a

representation of series operation.

Figure 3.2 Series Operation

Positive Load

Negative Load

Terminal

Terminal

Positive Output

Negative Output

Return Sense

Terminal

Terminal

Positive Sense

Negative Output

Positive Output

Return Sense

Positive Sense

Terminal

Terminal

Note

You do not need to use remote sensing for series operation. If you choose to use

it, refer to

“Remote Sensing” on page 33

.