Figure 3.3 parallel operation – Xantrex Technology XPD 60-9 User Manual

Page 44

Advertising
background image

Section 3. Local Operation
Using Multiple Supplies

42

Operating Manual for XPD Series Power Supply

Configuring Multiple Supplies for Parallel Operation

Connect power supplies in parallel to obtain a single output supply with a higher
output current limit. Set all of the outputs to the same voltage before connecting the
positive (

+) and negative (−) terminals in parallel. The total current available is the

sum of the maximum currents of each supply.

The maximum voltage available at the load is equal to the voltage of the lowest rated
supply. When you connect two supplies in parallel, the supply with the higher
voltage setting will be in the current limiting mode, while the other supply controls
the output voltage.

Figure 3.3 Parallel Operation

!

CAUTION
For parallel operation , set all OVP trip points higher than the maximum output
voltage.

Positive Sense

Terminal

Terminal

Return Sense

Positive Output

Negative Output

Positive Output

Return Sense

Negative Output

Terminal

Terminal

Positive Sense

Positive Load

Terminal

Terminal

Negative Load