Section 1. Features and Specifications

Environmental Specifications

Release A

21

Environmental Specifications

Mechanical Specifications

Operating Temperature Range

0 to 50 °C

Storage Temperature Range

-40 to 85 °C

Humidity Range

Up to 95% RH non-condensing

Operating Altitude

Maximum 6,500 feet (2,000 m)
Derate maximum operating temperature by
1 °C per 1,000 feet (300 m) for operation
between 5,000 feet (1500 m) and 6,500 feet
(2,000 m)

Storage Altitude

Up to 50,000 feet (15 000 m)

Installation Category

II

Pollution Degree

2

Front Panel Voltage and Current
Control

10-turn voltage and current potentiometers

Front Panel Voltage Control Resolution 0.02% of maximum voltage

Front Panel Current Control Resolution 0.02% of maximum current

Front Panel Voltage and Current
Meters

3-digit green numeric LED displays. For
meter accuracy, see

Table 1.3, on page 18

AC Input Connector Type

IEC 320 connector, appropriate power cord
provided for destination country

Input Fuses

Non-user accessible, both lines fused.

Output Connector

Front panel: 5-way binding posts maximum
current limit 30 A
Rear panel: 7.5–18 V models: bus bars with
0.3” holes. 33–120 V models: wire clamp
connectors

Sense Connector

5 terminal wire clamp connector

Analog Programming Connector

15-pin female DSUB connector

Chassis Ground

Front panel binding post; chassis is
grounded through power cord

Cooling

Fan cooled. Variable speed fan. Air flows
from front to rear, with vents on top, bottom,
and sides