Section 3. Local Operation
Standard Operation

36

Operating Manual for XPD Series Power Supply

Figure 3.1 Operating Modes

Constant

Voltage Mode

Operation

The power supply will operate in constant voltage mode whenever the load current
I

L

is less the current limit setting I

SET

, or: I

L

< I

SET

(Note: I

L

= V

SET

/ R

L

). In

constant voltage mode, the power supply maintains the output voltage at the selected
value (V

SET

) while the load current I

L

varies with the load requirements.

To use the power supply in Constant Voltage mode, either set the current limit to
maximum by turning the current control to its extreme clockwise position, or take
the precaution of setting a desired maximum current, then set the voltage control to
the desired voltage.

Constant

Current Mode

Operation

The power supply will operate in Constant Current mode whenever the load
resistance is low enough that the load current I

L

is greater than the current limit

setting I

SET

, or: I

L

> I

SET

. In constant current mode, the power supply maintains the

output current at the selected value (I

SET

) while the load voltage varies with the load

requirements.

Setting the

Current Limit

Set the Current Limit by following the steps below:

1. Connect a shorting lead across the output terminals.
2. Turn the voltage control a half-turn clockwise.
3. Set the desired maximum current limit by turning the current control slowly

clockwise to the desired level.

Output
Voltage

Constant Voltage
Mode Region

V

SET

0

0

I

SET

Output
Current

R

L

V

SET

I

SET

Crossover Point R

L

V

SET

I

SET

R

L

V

SET

I

SET

Constant Current
Mode Region

Where

R

L

V

SET

I

SET

Load Resistance

Output Voltage Setting

Output Current Limit Setting

Note

The control circuits have been designed to allow you to set output voltage and

current up to 1.5% over the model-rated maximum values. The power supply will
operate within these extended ranges, but we cannot guarantee full performance to
specification.