11. Connecting External Signal Control

Remove the cover of the battery

compartment on the back of the unit

by pushing down the top side of the

cover, and then release it from the two

clasps.

1

72

66

CAUTION: Disconnect the ES1000 from the AC Power before connecting the External

Signal Relay. Improper connection may cause a malfunction of the unit.

Also make sure to secure wires with the wire clamp.

If external signal(s) are required, the addition of a relay (not supplied) will be necessary.

Please consult your local electrician.

When a signal is activated the internal contacts close completing the circuit. These internal

contacts are "dry" and supply no voltage. Voltage applied to these contacts must not exceed

30 volts. An external relay must be used to activate signaling devices.

Recommended Relays: (Or similar line voltage switching relays)

Available at W. W. Grainger

HoneyWell

#RA89A1074

Grainger #2E866

Dayton

#809A-189

Grainger #2E553

Connections shown for Dayton 2E553. Add jumper from terminals 1 to 3.

External

Relay

ES1000

Internal

Relay

120 VAC

External

Signal

2

1

3

4

Nuetral

30V

Class 2