Gpis out - function, Gpis out - type, Gpis out - advance – EVS XS Version 11.02 - July 2013 Configuration Manual User Manual
Page 168: Gpis out - pulse duration

GPIs OUT - Function
Description
Specifies the function that activates the output line.
Values
The following functions can be triggered by a GPI OUT:
•
Replace
GPIs OUT - Type
Description
Specifies the type of GPI output signal that will trigger the
specified function.
Values
The following values are possible:
•
close
The level changes to high level at
activation.
•
close
pulse
A rising edge pulse is generated at
activation.
•
open
The level changes to low level at
activation.
•
open
pulse
A falling edge pulse is generated at
activation.
GPIs OUT - Advance
Description
Defines the time (number of seconds and/or frames), at which
the output will be generated ahead of the timecode linked to the
output line.
Values
•
00s00fr to 02s00fr
•
Disable
Default value
Disable
GPIs OUT - Pulse duration
Description
Defines the pulse duration (number of seconds and/or frames)
for pulse type output lines.
Values
•
00s00fr to 02s00fr (2fr steps)
•
Disable
Default value
Disable
160
3. Multicam Configuration
EVS Broadcast Equipment S.A.
Issue 11.02.A July 2013