3.9.10. EVS Controller Settings
Introduction
The EVS Controller settings gather:
◦
Settings related to the behavior of the keys, lever or jog of the Remote Panel.
◦
Settings associated to XFile or the EVS server itself.
Warning
Most of the settings are only available or applicable with base configurations
associated to the use of an EVS Remote Panel (XSense Remote).
User Interface
These fields are available in the following interfaces:
•
in the Multicam Configuration window, Operation tab, in the basic display mode:
◦
on page 4 on the server-based application
◦
on page 1 on the web-based interface
•
in the Operational setup menu of the Remote Control Panel (9.X)
The following screenshot presents page 4 of the Operation tab in the server-based
application, where the EVS Controller settings are available:
Effect duration for take
Description
Defines the duration of the transition when using the TAKE key
to chain 2 sequences in PGM+PRV mode.
Values
Range of values: 00s00fr to 20s00fr.
Default value
00s05fr