Troubleshooting

Trebing & Himstedt Prozeßautomation GmbH & Co. KG | TH LINK

32

Troubleshooting

– Check the power supply (LED RUN must light green).

– Check for correct connection (RJ-45, see "Connecting to

Ethernet" on page 15).

– The TH LINK is preset to network operation with a DHCP

server (IP address for the TH LINK is assigned by the DHCP
server). If your network server does not support DHCP, you
need to set the IP address for the TH LINK yourself

(see "Connection in a network with manual IP address
assignment" on page 22
).

– When a crossover cable is used between PC/notebook and

TH LINK, both devices must be in the same subnet.

TH LINK as Passive PROFIBUS station:

– Check for proper connection (see "Connecting the

PROFIBUS" on page 28) and switch at Settings >
TH SCOPE

> Measurement the baud rate on Automatic

detection

.

TH LINK as Active/Passive PROFIBUS station:

– Check the PROFIBUS parameters for the used TH LINK (see

application software, not included in the scope of delivery).
Each station has its own station address, which can only be
assigned once in the network.

TH LINK is not found in the Ethernet network

PROFIBUS network is not found