Temp fault 24 – Banks Power Ford Trucks: (Diesel ’03 - 07 6.0L Power Stroke) Interface- PowerPDA For use with EconoMind Ford (03-09), Chevy(01-08), Dodge (03-07) User Manual
Page 24
The ‘On Screen Alert’ menu allows
you to configure the volume control
for alarms and the corresponding
parameter to be monitored. The
available alerts icons can be seen in
Figure 39.
Note: In the event an alert set point is
reached an audible alarm will sound
off and the Status Indicator will display
an icon relative to the associated
alert (Figure 40). The alarm will turn
off once the associated parameter is
below its alert set-point. The Status
Indicator will then return to ‘OK’.
1.
Press the center button on the
5-way navigator to take you to the
System Menu screen.
2.
Next, touch the ‘On Screen Alerts’
button.
3.
On the ‘Set Volume for Alerts’
screen, touch the desired sound level
to set the alarm level. See Figure 41.
4.
Touch the ‘Next’ button to move to
the ‘On Screen Alerts’ screen (Figure
42).
This selection allows you to set the
value at which the alert will occur
based on exhaust gas temperature.
The selection range is 1100˚ to 1700˚.
The default value is 1450˚.
Note: This is an alert only. The
EconoMind is calibrated to begin
de-fueling when 1350˚ is reached,
regardless of the Alert Setting.
Screen 1 of the ‘On Screen Alerts’
menu edits the ‘Exhaust Gas
Temperature Alert Set Point’.
Section 10
oN SCrEEN ALErTS
Figure 41
EXHAUST GAS TEMP
ENGINE COOLANT
ENGINE OIL TEMP
TRANSMISSION TEMP
ECONOMIND TUNER
Figure 39
Figure 40
TEMP
FAULT
24
96803 v.7.0