5. Sidewall Construction

PNEG-1276 Top Dry Autoflow Construction Manual 24', 30' and 36'

23

Sidewall Erection Instructions

Before bolting the sidewall sheets together, check that you have the proper gauge steel for the first ring.
The higher gauge numbers denote the thinner materials. (For example, 22 gauge material is thinner than
14 gauge.) In erecting most grain bins the thinnest material usually goes on top, therefore the first sidewall
ring you assemble will be the top ring of the bin. Check the various gauges of the bin with the color code
chart and begin building accordingly REMEMBER.....Assemble the top ring first.

Once you have selected the proper gauge material, begin assembling all sidewall sheets in the following
manner: Standing on the inside the bin, place the left panel to the inside with the right panel to the outside.

(See Figure 5A.)

Check to see that the sidewall sheet is “Right side up”.

Refer to Page 21

for details.

Figure 5A

Gauge

Color Code

22

White

20

Red

19

Black/Yellow

18

Orange

17

Pink/Light Blue

16

Blue

15

Brown/Red

14

Green

13

Yellow/Blue

12

Black

11

Pink

10

Light Blue

9

Blue/Orange

8

Yellow