8. Installation

PNEG-1276 Top Dry Autoflow Construction Manual 24', 30' and 36'

41

Flashing Bolt Installation

Install the eave flashing bolts (5/16" x 1-1/4") through the sidewall and tighten first nut. Note at the vertical
sidewall seams, one bolt is turned around to avoid interference with eave flashing
.

(See Figure 8H.)

Figure 8H

Eave Flashing Installation

Install the eave flashing centered on the floor sheet (1 per) with the bent edge towards the sidewall install
a fender washer (S-3671) and nut. Screw the flashing to the flashing angle at the dump hopper opening
with five (5) #10 self-drilling screws (S-280) and screw the flashing pieces together where they overlap
with three (3) #10 self-drilling screws (S-280).

(See Figure 8I below

and Figure 8J on Page 42.)

Figure 8I

Left bolt on the each vertical sidewall seam level
with the eave flashing bolts (as viewed from
inside the bin) is to be installed bolt in, nut out,
as shown in

Figure 8H

.

Flashing Attachment

1) Sidewall
2) Flashing (TD-100648)
3) Floor sheet
4) 5/16" x 1-1/4" Bin bolt

Note that there is a nut in between the
sidewall sheet and the flashing sheet.

Advertising