9. Assembly

PNEG-1276 Top Dry Autoflow Construction Manual 24', 30' and 36'

55

Center Cone Assembly

Bolt the sections together to form perforated cone as shown in

Figure 9E

. Use 1/4" x 5/8" bolts and nuts

to attach sections together.

Figure 9E

Center Cone Installation

After chains have been adjusted, install cone over the center collar. Fasten cone assembly with
twelve (12) #10 x 3/4" self-drilling screws (S-280).

(See Figure 9F.)

Figure 9F