6. Stiffener Details

PNEG-1276 Top Dry Autoflow Construction Manual 24', 30' and 36'

31

Bolting Requirements

Two (2) Stiffeners per Sidewall Sheet

All bolts are standard bin bolts with neoprene washers. For horizontal and vertical seam bolts, the bolt
head and neoprene washers are on the outside of the bin.

NOTE: For the splice plates (FC-42076), use 5/16" x 1-1/4" bolts for the stiffener to sidewall connections.

Figure 6E Standard (17 gauge through 20 gauge) Sheet Bolting Detail (Viewed from outside of the bin.)

Stiffener and Seam Locations

Figure 6F

Sidewall Gauge

Horizontal Seam

Vertical Seam

Stiffener to Sidewall

Overlap Seam

17 through 20

5/16" x 3/4" [10]

5/16" x 3/4" [42]

5/16" x 3/4" [20]

5/16" x 3/4" [2]